Key features
Type: Roof extract
Application: Commercial/Industrial
Control options: Auto changeover/Duty sharing
The range

A high performance range of roof mounted run and standby fans with bottom inlet. Ideally suited where powerful low noise ducted ventilation is required.

Ideal where a duty standby fan is required, particularly where hygiene standards are critical: kitchens, restaurants, hotels, pubs, offices, factories, schools and shops.

Designed for roof installations where inside space and access is at a premium, Xpelair XDR units connect directly to extract duct work.

Xpelair XDR fans can be fitted directly to a weathered upstand or plenum box. Once fitted access for planned maintenance is from the outside with easy access to the motors. A run and standby and duty sharing controller is available which senses motor current.

Alternative designs, such as units with rear inlet and air input versions are also available to special order. Please contact Xpelair CustomVent Division where we specialise in bespoke solutions. Further details page 288.

Further details

 XDR600XDR500/5XDR500/3XDR500/2XDR500/4XDR500/1XDR400/3XDR400/2XDR400/1XDR315/2XDR315/1XDR250XDR200XDR150XDR125XDR100
Spigot diameter (mm)6005005001500500400400400315315250200105125100
Airflow (m3/s) 0Pa0.000.000.001.551.891.280.001.050.720.700.560.540.240.190.130.07
Airflow (m3/s) 50Pa0.001.950.001.471.801.190.001.020.700.680.530.510.230.190.120.07
Airflow (m3/s) 100Pa0.001.850.001.391.691.100.000.980.680.660.490.460.210.180.120.06
Airflow (m3/s) 150Pa0.001.740.001.281.580.970.000.950.660.640.430.400.190.170.110.06
Airflow (m3/s) 200Pa2.751.620.001.171.440.831.000.910.640.620.330.300.180.160.110.05
Airflow (m3/s) 250Pa2.701.390.001.001.240.600.920.850.580.560.030.030.150.140.100.05
Airflow (m3/s) 275Pa0.000.000.000.000.000.000.000.800.530.520.000.000.140.120.090.04
Airflow (m3/s) 300Pa2.641.040.000.780.780.200.860.750.480.470.000.000.120.110.080.04
Airflow (m3/s) 325Pa0.000.000.000.000.000.000.000.680.350.340.000.000.100.090.070.03
Airflow (m3/s) 350Pa2.640.600.000.110.000.000.750.580.170.160.000.000.070.070.050.00
Airflow (m3/s) 375Pa2.500.000.000.000.000.000.000.140.000.000.000.000.050.040.030.00
Airflow (m3/s) 400Pa2.220.001.610.000.000.000.400.010.000.000.000.000.010.010.000.00
Airflow (m3/s) 450Pa1.740.001.530.000.000.000.200.000.000.000.000.000.000.000.000.00
Nominal fan speed (rpm)84080013008007707101130121011001100130013001150115011502150
Max electrical power (W)3700175026001400170011001050110070070036036019519519588
Full load current (A)7.003.004.302.607.805.204.706.003.003.001.601.601.001.001.000.50
Starting current (A)20.0011.0017.5011.0010.009.008.8016.007.507.504.504.503.003.003.001.00
Motor insulation classFFFFFFFFBBFFBBBB
IP ratingIP54IP54IP54IP54IP54IP54IP54IP44IP44IP44IP44IP44IP44IP44IP44IP44
Max operating temperature (ºC)                
Weight (kg)19212412012013812086726464403225242423
PhaseThree PhaseThree PhaseThree PhaseThree PhaseSingle PhaseSingle PhaseSingle PhaseSingle PhaseSingle PhaseSingle PhaseSingle PhaseSingle PhaseSingle PhaseSingle PhaseSingle PhaseSingle Phase

Casings

Unit casings are manufactured from best quality marine grade aluminium with access from top. Standard mounting are on to builder’s work curb. All permanent fixings are rivetted and all removable items are retained via setscrews and nutserts. Fan mounting plate incorporates ‘damped panel’ technology and is easily removable via access panel.

Fan Deck

Incorporates 'damped panel technology' developed to considerably reduce fan deck resonance. Xpelair's visco-elastic polymer laminate construction is particularly effective at reducing resonance in the lower frequency octave bands.

Fans

Single-inlet, single width, or double-inlet, doublewidth, centrifugal type with high efficiency, low noise, forward- curved, multiblade galvanised sheet steel impellers housed within galvanised steel scrolls. Motor/impeller assemblies are statically and dynamically balanced, in two planes, in accordance with BS 5265, Part 1, 1979 to G2.5. Fans are mounted individually on to fan decks to Facilitate easy removal.

Motors

Motors are totally enclosed, high-efficiency, splitcapacitor, external rotor type with power factors of better than 0.9. Max. ambient operating temp. at least 40°C. (Motors rated to 50ºC are available to special order.) Bearings are sealed-for-life, maintenance-free, ball bearing type with a minimum life expectancy of 50,000 hours under design operating conditions. Thermal contactors are incorporated into the windings to ensure overload protection. Insulation is to Class B or F with enclosure to IP44 or IP54. Electrical supply is 220-240V single phase 50Hz or 400-415V three phase 50Hz.

Terminal Box

Electrical connections are wired via an external IP54 terminal box, with removable cover, in accordance with I.E.E. 16th. Edition, (BS7671), and tested to ensure full earth continuity. Auto changeover with duty sharing run and standby is used with this model.