Commercial wall fans
Stylish commercial duty unit ventilation designed for pubs, restaurants, offices, kitchens, factories, schools and shops.
Key features
Type: Commercial duty ventilation unitApplication: Pubs, restaurants, offices, kitchens, factories, schools and shops
Control options: Extensive range of optional controllers available
Legislation: Conforms to Building Regulations
Hole diameter: w245 x h268 - WX6/WX6T, w345 x h375 - WX9, w434 x h434 - WX12
The range
Xpelair WX ventilation units – the ‘classic’ face of commercial wall fans. Discretely slim, tough and reliable within – a winning formula that has served generations of pubs, businesses and local authorities.Stylish commercial duty unit ventilation designed for pubs, restaurants, offices, kitchens, factories, schools and shops.
Suitable for single, cavity brick and current timber frame walls.
The wall hugging, low profile white fascia is styled to blend in cleanly with commercial surroundings. For safety, a finger guard is integrated into the Ultra slim high gloss ABS fascia and the exterior wall grille design. On WX9 & WX12 units a positive plug and socket assembly provides a means of isolation for service access without the safety risk of accidental disconnection.
All WX models come complete with a wall mounting kit which include a wall liner.
Both the WX9 & WX12 are reversible and now feature totally enclosed external rotor motors providing constant volume outputs, even in gusty external conditions.
Pre-balanced sickle bladed impellers eliminate’ fan judder’ and ensure quiet trouble free operation. Sealed for life maintenance free bearings ensure suitability for running at any angle. Running costs are impressively low, and when not in use the silent electro-thermal shutter cassette closes silently against backdraughts.
And cleaning has never been easier. The housing, shutter cassette and impeller are all removed in seconds.
Further details
BEAB
CE
Single Fan Controller FR22/30
Ref. 21868AW
Group Fan Controller EC6H
Ref. 21854AW
Group Fan Controller XCC1
Ref. 21859AW
Ref. 21868AW
- For use with GX9 and GX12
- On/Off control with neon indicator
- Used to select between high and low speed, intake and extract
Group Fan Controller EC6H
Ref. 21854AW
- For use with GX6 and GX12
- On/Off control with neon indicator
- Infinitely variable speed selection controls extract and intake air flow. For use with up to four fans (not mixed sizes)
Group Fan Controller XCC1
Ref. 21859AW
- For use with GX9 and GX12
- On/Off control with neon indicator
| WX12 | WX9 | WX6T | WX6 | |
|---|---|---|---|---|
| Reference number | 90011AW | 89996AW | 90823AW | 90822AW |
| Remote switch (not supplied) | yes | yes | yes | yes |
| Integral adjustable run-on timer (2 to 20 mins) | no | no | yes | no |
| Extract only | no | no | yes | yes |
| Selectable intake, extract or controller operation | yes | yes | no | no |
| Speeds | 2 (controller options apply) | 2 (controller options apply) | 1 | 1 |
| Extract performance (FID, m3/h) - high | 1715 | 783 | 246 | 246 |
| Extract performance (FID, m3/h) - low | 645 | 663 | - | - |
| Extract performance (FID, l/s) - high | 476 | 248 | 68 | 68 |
| Extract performance (FID, l/s) - low | 179 | 184 | - | - |
| Intake performance (FID, m3/h) - high | 969 | 477 | - | - |
| Intake performance (FID, m3/h) - low | 815 | 437 | - | - |
| Intake performance (FID, l/s) - high | 269 | 133 | - | - |
| Intake performance (FID, l/s) - low | 226 | 121 | - | - |
| Sound pressure level (dB(A)@3m) - high | 54 | 50 | 39 | 39 |
| Sound pressure level (dB(A)@3m) - low | 48 | 47 | - | - |
| Electrical power rating (W) | 85 | 41 | 34 | 34 |
| Weight (kg) | 8.3 | 4.7 | 2.9 | 2.9 |
| Hole size (H x W mm) | 434x434 | 375x345 | 268x245 | 268x245 |
| Max wall thickness (mm) | 522 | 508 | 292 | 292 |
| Guarantee (years, UK) | 3 | 3 | 3 | 3 |
| Manuals | WX6 & WX6T Instructions.pdf |
Performance:


All dimensions in mm

Wiring:

WX6
Ref. 90822AW
WX6T
Ref. 90823AW:
Ref. 90822AW
- 6” high performance extract axial ventilation unit
- Suitable for single, cavity brick and current timber frame walls
- Sealed for life maintenance free bearings, suitable for running at any angle. Integrated safety thermal overload protection
- Built-in silent action electrothermal shutter cassette
- Passive tricklevent facility for background ventilation with fan Off
- Ultra slim high gloss ABS facia with integral finger safety guard
- Shadow grey external grille for unobtrusive external appearance with built-in weather protection
WX6T
Ref. 90823AW:
- As WX6 with overrun timer which typically connects to a lighting circuit
- Timer adjustable from 2-20mins run on period after light has been switched off
WX9
Ref. 89996AW
WX12
Ref. 90011AW:
- High performance intake/extract axial ventilation unit
- Choice of optional controllers
- Suitable for single, cavity brick and current timber frame walls
- Balanced external rotor motor and impeller for quiet efficiency
- Sealed for life maintenance free bearings, suitable for running at any angle
- Built-in silent action electro-thermal shutter cassette
- Passive tricklevent facility for background ventilation with fan Off
- Ultra slim high gloss ABS facia with integral finger safety guard
- Shadow grey external grille for unobtrusive external appearance with built-in weather protection
- Tamperproof internal connection safety plug and socket
- High performance intake/extract axial ventilation unit
The unit is to be supplied from the Xpelair WX range by Applied Energy Products Ltd. Morley Way, Peterborough PE2 9JJ
Tel. +44 (0)1733 456789
Model / Ref
WX6 / 90822AW
WX6T / 90823AW
WX9 / 89996AW
WX12 / 90011AW
Tel. +44 (0)1733 456789
Model / Ref
WX6 / 90822AW
WX6T / 90823AW
WX9 / 89996AW
WX12 / 90011AW
- The fan shall be suitable for wall mounting
- Installation shall be mortar free and the product shall be supplied complete with wall liner
- Performance shall have been proven by type testing in accordance with BS 848 Part 1 and FID performance determined to be:
(m3/h) / extract / intake
WX6(T) / 246 / -
WX9 / 783 / 477
WX12 / 1715 / 969
- All models shall have totally enclosed AC motors with sealed for life bearings, with external rotor motors on WX9 / WX12, and safety thermal overload protection
- The high efficiency moulded axial bladed impeller shall be pre-balanced and designed for optimum performance and ease of removal for cleaning
- Motor/impeller assembly shall be in a rigid ABS housing with high gloss white finish and incorporate a finger guard
- A passive trickle vent option shall be incorporated into the inner grille shutter cassette to provide low level ventilation when the unit is not in use
- The shutter shall be operated by a silent electrothermal actuator
- It shall be possible to remove the inner grille and shutter cassette separately for cleaning
- An outer grille shall be provided, this to be moulded in Shadow Grey ABS with high gloss finish and incorporate weatherproof vanes
- On WX9 and WX12 models customer electrical connection shall be via an internal tamper-proof plug and socket
- On WX9 and WX12 models a concealed switch on the unit shall predetermine the mode of operation: intake only, or extract only or optional controller operation for speed control and reversibility
- The unit shall be BEAB approved.
- Overall internal projection shall be:
WX6 = 11mm
WX9 / WX = 12 18mm
- All models shall have totally enclosed AC motors with sealed for life bearings, with external rotor motors on WX9 / WX12, and safety thermal overload protection