Key features
Type: Inline single speed axial extract fans and systemsApplication: Domestic bathrooms and shower rooms
Control options: Standard or timer
Legislation: Conforms to Building Regulations
Hole size: 115mm (XIL100/XXS100), 140mm (XIL125), 165mm (XIL150)
The range
Step out of the shower cubicle. Is the mirror ‘steamed over’?...there is another way.Remove the cause of condensation at source with an Xpelair inline shower fan system.
With a neat grille installed directly over the shower, humid or moist air will be ducted away by a fan above the ceiling and onwards to a grille installed outside, typically in the soffit.
Will I be standing in a draught? No, air will not be pulled into a normal cubicle, only flow over it.
XIL fans are available in sizes of 100, 125 & 150mm and are only available as fan systems. The systems contain all the components necessary for a normal installation, comprising:
- inline fan
- 3m of flexible duct
- Four worm drive clips
- inline backdraught shutter (XIL100)
- Internal ceiling grille with sleek styling in white
- Outside soffit/wall grille
XXS100 fans are available on their own.
All electronics circuits and wiring terminals are fully protected. Motors are Class B lubricated for life, fitted with safety thermal overload protection and suitable for ambient temperatures up to 40ºC.
Xpelair XIL systems conform to Building Regulations mechanical ventilation for toilets shower rooms and bathrooms.
Further details
BEAB
CE

2yr Guarantee

3yr Guarantee
| XXS100T | XXS100 | XIL150T | XIL150 | XIL125T | XIL125 | XIL100T | XIL100 | |
|---|---|---|---|---|---|---|---|---|
| Reference number | 90332AW | 90331AW | 91245AW | 91244AW | 91243AW | 91242AW | 90330AW | 90329AW |
| Fan only | yes | yes | no | no | no | no | no | no |
| Fan system (installation pack) | no | no | yes | yes | yes | yes | yes | yes |
| Remote switch (not included) | yes | yes | yes | yes | yes | yes | yes | yes |
| Integral timer (adjustable) | yes | no | yes | no | yes | no | yes | no |
| Extract performance (m3/h*) | 85 | 85 | 133 | 133 | 63 | 63 | 46 | 46 |
| Extract performance (l/s*) | 24 | 24 | 37 | 37 | 18 | 18 | 13 | 13 |
| Sound pressure level (dBA)@3m) | 33 | 33 | 45 | 45 | 43 | 43 | 30 | 30 |
| Electrical power rating (W) | 12 | 12 | 25 | 25 | 20 | 20 | 12 | 12 |
| Weight (kg) | 0.8 | 0.8 | 2.1 | 2.1 | 1.83 | 1.83 | 0.9 | 0.9 |
| Duct diameter (mm) | 100 | 100 | 150 | 150 | 125 | 125 | 100 | 100 |
| Hole size (mm) | 115 | 115 | 165 | 165 | 140 | 140 | 115 | 115 |
| IP rating | IPX2 | IPX2 | IPX2 | IPX2 | IPX2 | IPX2 | IPX2 | IPX2 |
| Guarantee (years, UK) | 2 | 2 | 2 | 2 | 2 | 2 | 3 | 3 |
Performance:



All dimensions in mm

XIL100
Ref. 90329AW:
Single speed Inline showerfan system
Operated by remote switch (in a bathroom whether by remote pullcord switch or wired to the lighting circuit)
Can also be wired to a water flow switch fitted in the pipework to the shower control to switch On/Off when the shower is in use
XIL100T
Ref. 90330AW:
Single speed inline showerfan system
Built-in overrun timer (adjustable at installation from 2-20mins)
Operated by remote switch (in a bathroom wired to the lighting circuit)
Can also be wired to a water flow switch, fitted in the pipework to the shower control, to switch On/Off when the shower is in use
XIL125
Ref. 91242AW:
Single speed inline showerfan system
Operated by remote switch (in a bathroom either by a remote pullcord switch or wired to the lighting circuit)
Can also be wired to a water flow switch fitted in the pipework to the shower control to switch On/Off when the shower is in use
XIL125T
Ref. 91243AW:
Single speed inline showerfan system
Built-in overrun timer (adjustable at installation from 3-15mins)
Operated by remote switch (in a bathroom wired to the lighting circuit)
Can also be wired to a water flow switch, fitted in the pipework to the shower control, to switch On/Off when shower is in use
XIL150
Ref. 91244AW:
Single speed inline showerfan system
Operated by remote switch (in a bathroom either by a remote pullcord switch or wired to the lighting circuit)
Can also be wired to a water flow switch fitted in the pipework to the shower control to switch On/Off when the shower is in use
XIL150T
Ref. 91245AW:
Single speed inline showerfan system
Built-in overrun timer (adjustable at installation from 3-15mins)
Operated by remote switch (in a bathroom wired to the lighting circuit)
Can also be wired to a water flow switch, fitted in the pipework to the shower control, to switch On/Off when shower is in use
XXS100
Ref. 90331AW:
Single speed inline fan
Operated by remote switch
XXS100T
Ref. 90332AW:
Single speed inline fan
Integral timer operated by remote switch (adjustable from 2-20mins)
Ref. 90329AW:
XIL100T
Ref. 90330AW:
XIL125
Ref. 91242AW:
XIL125T
Ref. 91243AW:
XIL150
Ref. 91244AW:
XIL150T
Ref. 91245AW:
XXS100
Ref. 90331AW:
XXS100T
Ref. 90332AW:
The unit is to be supplied from the Xpelair XIL range by Applied Energy Products Ltd, Morley Way, Peterborough PE2 9JJ
Tel. +44 (0)1733 456789
Model / Ref
XIL System:
XIL100 / 90329AW
XIL125 / 91242AW
XIL150 / 91244AW
XIL T System with integral overrun timer:
XIL100T / 90330AW
XIL125T / 91243AW
XIL150T / 91245AW
XXS100 fan only / 90331AW
XXS100T fan only / 90332AW
The system shall comprise:
Tel. +44 (0)1733 456789
Model / Ref
XIL System:
XIL100 / 90329AW
XIL125 / 91242AW
XIL150 / 91244AW
XIL T System with integral overrun timer:
XIL100T / 90330AW
XIL125T / 91243AW
XIL150T / 91245AW
XXS100 fan only / 90331AW
XXS100T fan only / 90332AW
The system shall comprise:
- Inline fan
- 3m of 100mm dia. flexible duct
- Four fixing clips
- Inline backdraught shutter
- Internal ceiling grille in white
- Outside soffit/wall grille in brown
- T models shall include overrun timer function adjustable between 2 - 20mins (100 range) and 3 - 15mins (125/150 ranges)
- The fan housing and grilles shall be moulded in ABS. The internal and external grilles should have finger guard protection. The fan and air operated backdraught shutter shall be installed in the space above the ceiling at the highest point in the system
- The motor shall be lubricated for life with built in safety thermal overload protection
- The fan shall comply with Building Regulations for use in bathrooms and shower rooms when typically installed