Centrifugal extract and condensation control fans
The Premier range of pressure developing fans is designed specifically for domestic applications, where longer duct runs are required.
Key features
Type: DX centrifugal extract and CF condensation control fansApplication: Domestic bathrooms, shower rooms, toilets and utility rooms
Control options: Pull cord, timer and humidistat
Legislation: Conforms to Building Regulations
Hole size: 117mm (wall) 120mm (window)
The range
The efficient and stylish Premier range of pressure developing fans is designed specifically for domestic applications, including bathrooms, shower rooms toilets and utility rooms where longer duct runs are required. They are also suitable for commercial applications such as hotel rooms, office toilets, commercial bathrooms, and for coastal installations.All models have a gloss white casing with clean and sleek appearance. A two part casing means Premier fans can easily be recessed or surface mounted. They can be fitted into ceilings or studwork walls in recesses as little as 50mm deep using the side entry knockout provided, an FDA adaptor and Profile 29 flat duct. Alternatively 100mm circular ducting can be used. All feature an automatic air operated back draught shutter and the CF20 range are supplied with a brown 100mm external outlet grille for wall or soffit fixing.
The clip off front cover and removable fan blade on all models allow easy cleaning and maintenance. All also have a neon indicator (except DX180/T).
DX200 and CF20 models are IPX5 rated where-as the DX180 models are IPX4. All are BEAB approved. They are all suitable for 220-240Vac 50Hz mains operation. Motors are totally enclosed and maintenance free for life, with self aligning bearings and a thermal cut-out. All electronics and wiring terminals are fully protected.
Further details
BEAB
CE

3yr Guarantee
Zone 1
Zone 2
Manual Override Switch MOS
Ref. 90199AW
Remote Humidistat XRH
Ref. 21856AW
Remote Time Delay Unit DT20B
Ref. 21850AW
Passive Infrared Sensor XPIRA
Ref. 21871AA
Ref. 90199AW
- Provides switching between manual and automatic operation. For use in conjunction with remote humidistat
Remote Humidistat XRH
Ref. 21856AW
- Stand alone humidistat switches fan On/Off when RH reaches pre-set levels. Complete with pullcord override switch
Remote Time Delay Unit DT20B
Ref. 21850AW
- User adjustable run-on timer (2-20mins)
Passive Infrared Sensor XPIRA
Ref. 21871AA
- Activates fan via body movement
- Ideal for infrequently used public spaces
- Built in timer to prevent nuisance tripping
| CF20T | CF20 | DX200T | DX200 | DX180H | DX180T | DX180 | |
|---|---|---|---|---|---|---|---|
| Reference number | 91016AW | 91015AW | 91014AW | 91013AW | 91183AW | 91182AW | 91181AW |
| Integral pullcord | yes | yes | no | no | no | no | no |
| Integral adjustable run-on-timer (30s to 20 mins) | yes | no | yes | no | no | yes | no |
| Integral fixed run-on timer (20 mins) | no | no | no | no | no | yes | no |
| Humidity sensor (50-90% RH) | yes | yes | no | no | yes | no | no |
| Quick visit facility (2 minutes) | yes | no | yes | no | no | no | no |
| Speeds | 5 | 5 | 4 | 2 | 1 | 1 | 1 |
| Trickle ventilation facility | yes | yes | yes | no | no | no | no |
| Extract performance (FID, m3/h) boost | 108 | 108 | - | - | - | - | - |
| Extract performance (FID, m3/h) speed 3 | 102 | 102 | 108 | - | - | - | - |
| Extract performance (FID, m3/h) speed 2 | 79 | 79 | 79 | 108 | - | - | - |
| Extract performance (FID, m3/h) speed 1 | 50 | 50 | 50 | 50 | 94 | 94 | 94 |
| Extract performance (FID, m3/h) trickle | 36 | 36 | 36 | - | - | - | - |
| Extract performance (FID, l/s) boost | 30 | 30 | - | - | - | - | - |
| Extract performance (FID, l/s) speed 3 | 28 | 28 | 30 | - | - | - | - |
| Extract performance (FID, l/s) speed 2 | 22 | 22 | 22 | 30 | - | - | - |
| Extract performance (FID, l/s) speed 1 | 14 | 14 | 14 | 14 | 26 | 26 | 26 |
| Extract performance (FID, l/s) trickle | 10 | 10 | 10 | - | - | - | - |
| Sound pressure level (dB(A)@3m) boost | 50 | 50 | - | - | - | - | - |
| Sound pressure level (dB(A)@3m) speed 3 | 48 | 48 | 50 | - | - | - | - |
| Sound pressure level (dB(A)@3m) speed 2 | 42 | 42 | 42 | 50 | - | - | - |
| Sound pressure level (dB(A)@3m) speed 1 | 32 | 32 | 32 | 32 | 49 | 49 | 49 |
| Sound pressure level (dB(A)@3m) trickle | 26 | 26 | 26 | - | - | - | - |
| Electric power rating (W) | 34 | 34 | 34 | 34 | 26 | 26 | 26 |
| Weight (kg) | 1.75 | 1.75 | 1.75 | 1.75 | 2.0 | 2.0 | 2.0 |
| IP rating | IPX5 | IPX5 | IPX5 | IPX5 | IPX4 | IPX4 | IPX4 |
| Guarantee (years) | 3 | 3 | 3 | 3 | 3 | 3 | 3 |
Performance:



All dimensions in mm

Premier DX180
Ref. 91181AW:
Premier DX180T
Ref. 91182AW:
Premier DX180H
Ref. 91183AW
Premier DX200
Ref. 91013AW
Premier DX200T
Ref. 91014AW
Premier CF20
Ref. 91015AW
Premier CF20T
Ref. 91016AW
Ref. 91181AW:
- Single speed centrifugal unit
- Operated by remote switch
Premier DX180T
Ref. 91182AW:
- Single speed centrifugal unit with timer
- Built-in fixed 20mins run On period after the light has been switched Off
Premier DX180H
Ref. 91183AW
- Single speed centrifugal unit with humidistat
- On/Off humidistat adjustable 50-90% RH
Premier DX200
Ref. 91013AW
- High performance centrifugal unit
- Choice of 2 set speeds
Premier DX200T
Ref. 91014AW
- High performance centrifugal unit with timer
- Room size selector matches extract performance for improved efficiency
- ‘QuickVisit’ delay feature prevents fan from running should light be switched On/Off again within 2mins
- Mechanical trickle ventilation facility
- Built-in run-on period after light switched Off. User adjustable from 30s-20mins
Premier CF20
Ref. 91015AW
- High perfomance condensation control centrifugal unit
- Step-speed, user adjustable humidistat
- Room size selector matches extract performance for improved efficiency
- Tricklevent and pull cord manual override
- Includes external wall grille
Premier CF20T
Ref. 91016AW
- All the features of CF20 plus:
- Auto run-on after light switched Off
- ‘QuickVisit’ delay feature prevents fan from running should light be switched On/Off again within 2 mins
The unit is to be supplied from the Xpelair Premier range by Applied Energy Products Ltd, Morley Way, Peterborough PE2 9JJ
Tel. +44 (0)1733 456789
Model / Ref
DX180* / 91181AW
DX200 / 91013AW
DX180T* / 91182AW
DX200T / 91014AW
DX180H* / 91183AW
CF20 / 91015AW
CF20T / 91016AW
*IPX4 rated
Tel. +44 (0)1733 456789
Model / Ref
DX180* / 91181AW
DX200 / 91013AW
DX180T* / 91182AW
DX200T / 91014AW
DX180H* / 91183AW
CF20 / 91015AW
CF20T / 91016AW
*IPX4 rated
- The unit shall be designed for flush or surface mounting in walls, ceilings or through glass (using the GMK kit) and supplied complete with fixing clamps for flush mounting
- CF20 models shall be supplied with outside grille
- DX200 models shall have selectable speed running facility with speed selection at installation
- DX200T shall have an adjustable overrun timer (30s - 20min) with 2min start delay
- CF20 shall have automatic operation through integral humidity sensor, manual boost speed via pull cord and trickle ventilation
- CF20T shall have automatic operation through integral humidity sensor, manual boost speed via pull cord and trickle ventilation. Adjustable overrun timer (30s - 20min). Optional 2 min start delay
- It shall be possible to remotely select speeds using Xpelair switch Ref. 90108AW
- The unit shall be BEAB approved and rated at IPX5. The fan shall conform to Building Regulations for use in toilets, bathrooms and utility rooms. The fan shall incorporate an automatic air operated backdraught shutter
- The unit shall be suitable for zone 1 and zone 2 requirements as defined by IEE Wiring Regulations 16th Edition BS 7674:2001
- A rectangular cut out section shall be provided in the top of the fan housing to connect to Xpelair Profile kit Ref. 90547AA
- The housing and stylish air inlet shall be moulded in high gloss white ABS
- The front cover shall be held in position by the retaining clips to facilitate removal and adjustment
- The motor shall be totally enclosed, fitted with sealed self aligning maintenance free bearings and include thermal overload protection
- Dimensions shall be W x H x D
222mm x 252mm x 118mm excluding spigot