Centrifugal extract and condensation control fans
These pressure developing centrifugal fans are sleekly styled and are ideally suited for use in kitchens, utility rooms and larger bathrooms and toilets and individual offices.
Key features
Type: DX centrifugal extract and CF condensation control fansApplication: Domestic kitchens, utility rooms and larger bathrooms; commercial bathroom, small offices and public toilets
Control options: Pull cord, timer and humidistat
Legislation: Conforms to Building Regulations
Hole diameter: 115mm
The range
Kitchen ventilation has never looked so good. Since its launch, Premier has taken the ventilation market by storm. DX400 extract and CF40 condensation control fans are no exception. These pressure developing centrifugal fans are sleekly styled and are ideally suited for use in kitchens, utility rooms and larger bathrooms and toilets and individual offices.They can be surface or flush mounted in walls and ceilings using the universal mounting accessories provided, and include a back draught shutter and outlet grille. Both models have their inlet discreetly concealed behind a stylish white front cover. This cover is held in position by clips for easy removal for cleaning.
Control options include integral pullcord and timer. Models with an integral humidistat offer automatic control. CF40TD features a delay start ‘quick visit’ facility preventing the fan from coming on should the light be switched on and then off within 2 minutes.
All models are IPX5 rated and BEAB approved. They are all suitable for 220-240V 50Hz mains operation and feature external rotor motors with integral balanced impellers, sealed for life maintenance free bearings and safety thermal cut out protection.
Further details
BEAB
IPX5 rated
CE

3yr Guarantee
Manual Override Switch MOS
Ref. 90199AW
Change Over Switch COS
Ref. 90108AW
Remote Humidistat XRH
Ref. 21856AW
Remote Time Delay Unit DT20B
Ref. 21850AW
Passive Infrared Sensor XPIRA
Ref. 21871AA
Ref. 90199AW
- Switch 1 controls the high/low speed levels and
switch 2 controls On/Off and the tricklevent option
Change Over Switch COS
Ref. 90108AW
- Used to select between high and low speed operation
Remote Humidistat XRH
Ref. 21856AW
- Stand alone humidistat switches fan On/Off when RH reaches pre-set levels.
- Complete with pullcord override switch
Remote Time Delay Unit DT20B
Ref. 21850AW
- User adjustable run-on timer (2-20mins)
Passive Infrared Sensor XPIRA
Ref. 21871AA
- Activates fan via body movement
- Ideal for infrequently used public spaces
- Built in timer to prevent nuisance tripping
| CF40RSTD | CF40TD | CF40 | DX400RS | DX400PC | DX400T | DX400 | |
|---|---|---|---|---|---|---|---|
| Reference number | 91188AW | 91087AW | 91086AW | 91085AW | 91100AW | 91084AW | 91083AW |
| Remote switch (supplied separately) | no | no | no | yes | no | yes | yes |
| Remote switch (supplied) | yes | no | no | no | no | no | no |
| Integral pullcord | no | yes | yes | no | yes | no | no |
| Integral adjustable run-on-timer (30s to 20 mins) | yes | yes | no | no | no | yes | no |
| Humidity sensor (50-90% RH) | yes | yes | yes | no | no | no | no |
| Quick visit facility (2 minutes) | no | yes | no | no | no | yes | no |
| Speeds | 5 | 5 | 5 | 3 | 3 | 3 | 2 |
| Trickle ventilation facility | yes | yes | yes | yes | yes | yes | no |
| Extract performance (FID, m3/h) boost | 250 | 250 | 250 | - | - | - | - |
| Extract performance (FID, m3/h) speed 3 | 174 | 174 | 174 | - | - | - | - |
| Extract performance (FID, m3/h) speed 2 | 143 | 143 | 143 | 245 | 245 | 245 | 245 |
| Extract performance (FID, m3/h) speed 1 | 90 | 90 | 90 | 143 | 143 | 143 | 143 |
| Extract performance (FID, m3/h) trickle | 61 | 61 | 61 | 61 | 61 | 61 | - |
| Extract performance (FID, l/s) boost | 69 | 69 | 69 | - | - | - | - |
| Extract performance (FID, l/s) speed 3 | 48 | 48 | 48 | - | - | - | - |
| Extract performance (FID, l/s) speed 2 | 40 | 40 | 40 | 68 | 68 | 68 | 68 |
| Extract performance (FID, l/s) speed 1 | 25 | 25 | 25 | 40 | 40 | 40 | 40 |
| Extract performance (FID, l/s) trickle | 17 | 17 | 17 | 17 | 17 | 17 | - |
| Sound pressure level (dB(A)@3m) boost | 55 | 55 | 55 | - | - | - | - |
| Sound pressure level (dB(A)@3m) speed 3 | 46 | 46 | 46 | - | - | - | - |
| Sound pressure level (dB(A)@3m) speed 2 | 40 | 40 | 40 | 55 | 55 | 55 | 55 |
| Sound pressure level (dB(A)@3m) speed 1 | 33 | 33 | 33 | 42 | 42 | 42 | 42 |
| Sound pressure level (dB(A)@3m) trickle | 27 | 17 | 27 | 27 | 27 | 27 | - |
| Electrical power rating (W) | 77 | 77 | 77 | 78 | 78 | 78 | 78 |
| Weight (kg) | 3 | 3 | 3 | 3 | 3 | 3 | 3 |
| IP rating | IPX5 | IPX5 | IPX5 | IPX5 | IPX5 | IPX5 | IPX5 |
| Guarantee (years, UK) | 3 | 3 | 3 | 3 | 3 | 3 | 3 |
Performance:


Wiring:


Premier DX400
Ref. 91083AW:
Premier DX400T
Ref. 91084AW:
Premier DX400PC
Ref. 91100AW:
Premier DX400RS
Ref. 91085AW:
Premier CF40
Ref. 91086AW:
Premier CF40TD
Ref. 91807AW:
Premier CF40RSTD
Ref. 91088AW:
Note: For kitchen applications a grease filter PDXGF4 is recommended Ref. 91145AA
Ref. 91083AW:
- Two speed centrifugal fan
- Pre-select speed to suit application
- Alternatively use optional COS switch to change between speeds and On/Off
- Includes external wall grille
Premier DX400T
Ref. 91084AW:
- Two speed centrifugal fan with timer
- Alternatively use optional COS switch to change between speeds
- Timer is typically connected to lighting circuit
- Built in run-on period after the light has been switched Off, user adjustable from 30s-20min
- ‘QuickVisit’ delay feature prevents the fan from running should the light be switched On/Off again within two minutes
- Fan running status lights
- Includes external wall grille
Premier DX400PC
Ref. 91100AW:
- High, Low, On/Off with tricklevent operated by integral 3 position pullcord switch
- Fan running status lights
- Includes external wall grille
Premier DX400RS
Ref. 91085AW:
- Two speed centrifugal fan
- Pre-select speed to suit application
- Alternatively use optional COS switch to change between speeds and On/Off
- Trickle vent option is activated by a preset switch on the unit
- Fan running status lights
- Includes external wall grille
Premier CF40
Ref. 91086AW:
- Condensation Control Range with humidistat
- Automatic operation through integral humidity sensor
- Pullcord selects High, Low, Off or Trickle
Premier CF40TD
Ref. 91807AW:
- Automatic operation through integral humidistat
- Pullcord selects High, Low, Off or Trickle
- Timer is typically connected to a lighting circuit
- Built-in run-on period after the light has been switched Off, user adjustable from 30s-20min
- ‘QuickVisit’ delay feature prevents the fan from running should the light be switched On/Off again within two minutes
- Fan running status lights
- Includes external wall grille
Premier CF40RSTD
Ref. 91088AW:
- Automatic operation through integral humidistat
- MOS remote switch (supplied) selects high or low speed and can switch the unit Off (or to tricklevent)
- Timer is typically connected to a lighting circuit
- Built in run on period after the light has been switched off
- User adjustable from 30sec-20min
- Fan running status lights
- Includes external wall grille
Note: For kitchen applications a grease filter PDXGF4 is recommended Ref. 91145AA
The unit is to be supplied from the Xpelair Premier range by Applied Energy Products Ltd, Morley Way, Peterborough PE2 9JJ
Tel. +44 (0)1733 456789
Model / Ref
DX400 / 91083AW
DX400PC / 91100AW
DX400T / 91084AW
DX400RS / 91085AW
CF40 / 91086AW
CF40TD / 91087AW
CF40RSTD / 91088AW
Tel. +44 (0)1733 456789
Model / Ref
DX400 / 91083AW
DX400PC / 91100AW
DX400T / 91084AW
DX400RS / 91085AW
CF40 / 91086AW
CF40TD / 91087AW
CF40RSTD / 91088AW
- The unit shall be designed for flush or surface mounting in walls and ceilings using the fixing clamps provided
- An external grille shall be supplied with the fan
- DX400 fans shall have a two speed running facility and CF40 fans a room size selector in the control system to provide three preset speed settings for optimum room performance
- A further option of trickle ventilation shall be provided by way of a preset switch on the unit (not DX400)
- CF versions shall be manually adjustable between 50 and 90% RH with fan running status indicated by lights
- The unit shall be BEAB approved and rated IPX5. in addition the fan shall conform to Building Regulations for use in kitchens, utility rooms and bathrooms
- The fan housing shall be moulded in high gloss white ABS and be of modern design with the air inlet discreetly concealed behind a stylish baffle fixed to the front cover
- The front cover assembly shall be held in position by clips to facilitate ease of removal for fan adjustment
- The motor shall be of external rotor construction, IP44 rated with sealed maintenance free bearings and include inbuilt safety thermal overload protection
- A balanced impeller shall be integral with the motor assembly
- PC models shall be pullcord operated
- T models shall include integral timer function adjustable between 30s-20mins
- RS shall be remote switched. MOS Ref. 90199AW
- TD shall be integral timer
- RSTD shall be intergral timer and remote switched. MOS Ref. 90199AW
- Overall dimensions: W x H x D
249mm x 297mm x 147mm excluding spigot