Safety Extra Low Voltage ventilation
The Safety Extra Low Voltage (SELV) fans are ideal for use in shower rooms, bathrooms with showers and other zone 1 and zone 2 wet areas.
Key features
Type: LVDX centrifugal extract & LVCF condensation control fansApplication: Domestic bathrooms, shower rooms, toilets and utility rooms
Control options: Pull cord, timer & humidistat
Legislation: Conforms to Building Regulations
Hole size: 117mm (wall) 120mm (window)
The range
Splash about with complete peace of mind. The Safety Extra Low Voltage (SELV) versions of the Premier DX200 and CF20 pressure developing centrifugal fans are ideal for use in shower rooms, bathrooms with showers and other zone 1 and zone 2 wet areas. Whilst they are designed specifically for domestic applications, they are also suitable for commercial applications where walls are regularly hosed down. The SELV system consists of a 12V fan unit which can be safely installed in the spray area of a bath or shower, with the transformer located outside the spray area.Premier models LVDX200 & LVCF20 conform to Building Regulations covering mechanical ventilation for toilets, bathrooms and utility rooms. Importantly they exceed the IP requirements for zone 1 and zone 2 as defined by IEE Wiring Regulations (16th Edition) BS 7671:2001, and are rated IPX5. The motor is totally enclosed and fitted with self aligning bearings and thermal overload protection. The motor insulation is class B making them suitable for ambient temperatures up to 40ºC.
Premier SELV fans have the same clean and sleek styling as the rest of the Premier range, with a white gloss body and fascia. They are designed for easy installation in walls, ceilings, windows or ducted installation at any angle, and LVCF20 models come complete with a brown 100mm grille for wall or soffit fixing. All models come complete with a universal mounting kit and an automatic backdraught shutter.
The two part casing permits recessed or surface mounting, and can be fitted into ceilings and studwork wall recesses as little as 50 mm deep using the top entry knockout provided and an FDA adaptor and Profile 29 flat duct. Alternatively 100mm diameter circular duct can be used. A clip-off front and removable fan blade make for easy cleaning.
Further details
BEAB
IPX5 rated
CE

3yr Guarantee
Zone 1
Zone 2
| LVCF20T | LVCF20 | LVDX200T | LVDX200 | |
|---|---|---|---|---|
| Reference number | 91042AW | 91041AW | 91040AW | 91453AW |
| Remote switch (not supplied) | yes | no | no | yes |
| Integral pullcord | yes | yes | no | no |
| Integral adjustable run-on timer (30s to 20mins) | yes | no | yes | no |
| Humidity sensor (50-90% RH) | yes | yes | no | no |
| Quick visit (2 minutes) | yes | no | yes | no |
| Speeds | 5 | 5 | 2 | 2 |
| Trickle ventilation facility | yes | yes | - | no |
| Extract performance (FID, m3/h) boost | 108 | 108 | - | - |
| Extract performance (FID, m3/h) speed 3 | 102 | 102 | - | - |
| Extract performance (FID, m3/h) speed 2 | 79 | 79 | 108 | 108 |
| Extract performance (FID, m3/h) speed 1 | 50 | 50 | 45 | 45 |
| Extract performance (FID, m3/h) trickle | 36 | 36 | - | - |
| Extract performance (FID, l/s) boost | 30 | 30 | - | - |
| Extract performance (FID, l/s) speed 3 | 28 | 28 | - | - |
| Extract performance (FID, l/s) speed 2 | 22 | 22 | 30 | 30 |
| Extract performance (FID, l/s) speed 1 | 14 | 14 | 12.5 | 12.5 |
| Extract performance (FID, l/s) trickle | 10 | 10 | - | - |
| Sound pressure level (dB(A)@3m) boost | 50 | 50 | - | - |
| Sound pressure level (dB(A)@3m) speed 3 | 48 | 48 | - | - |
| Sound pressure level (dB(A)@3m) speed 2 | 42 | 42 | 50 | 50 |
| Sound pressure level (dB(A)@3m) speed 1 | 32 | 32 | 30 | 30 |
| Sound pressure level (dB(A)@3m) trickle | 26 | 26 | - | - |
| Electrical power rating (W) | 42 | 42 | 42 | 42 |
| Weight (kg) | 2.15 | 2.15 | 2.15 | 2.15 |
| IP rating | IPX5 | IPX5 | IPX5 | IPX5 |
| Guarantee (years) | 3 | 3 | 3 | 3 |
Dimensions:
All dimensions in mm 
Performance:



Premier LVDX200
Ref. 91453AW:
Premier LVDX200T
Ref. 91040AW:
Premier LVCF20
Ref. 91041AW:
Premier LVCF20T
Ref. 91042AW:
Ref. 91453AW:
- High performance centrifugal unit
- Stylish 2 piece fascia with neon indicator
- Choice of 2 set speeds
- Operated by remote switch eg. lighting circuit
Premier LVDX200T
Ref. 91040AW:
- High performance centrifugal unit with timer
- Stylish 2 piece fascia
- Operated by remote switch eg. lighting circuit
- ‘QuickVisit’ delay feature prevents fan from running should light be switched On/Off again within 2mins
- Built-in run-on period after light switched Off. User adjustable from 30s-20mins
- Neon indicator
Premier LVCF20
Ref. 91041AW:
- High perfomance condensation control centrifugal unit
- Integral condensation controller
- Stylish 2 piece fascia
- User adjustable humidistat (50-90% RH)
- Room size selector matches extract performance for improved efficiency
- Trickle ventilation facility
- Automatic or pull cord manual override
- Includes external wall grille
- Neon indicator
Premier LVCF20T
Ref. 91042AW:
- High perfomance condensation control centrifugal unit with timer (30s-20mins)
- Integral condensation controller
- Stylish 2 piece fascia
- User adjustable humidistat (50-90% RH)
- Room size selector matches extract performance for improved efficiency
- Operated by remote switch eg. lighting circuit
- Trickle ventilation facility
- Automatic or pull cord manual override
- Neon indicator
- Includes external wall grille
The unit is to be supplied from the Xpelair Premier range by Applied Energy Products Ltd, Morley Way, Peterborough PE2 9JJ
Tel. +44 (0)1733 456789
Model / Ref
LVDX200 / 91453AW
LVDX200T / 91040AW
LVCF20 / 91041AW
LVCF20T / 91042AW
Tel. +44 (0)1733 456789
Model / Ref
LVDX200 / 91453AW
LVDX200T / 91040AW
LVCF20 / 91041AW
LVCF20T / 91042AW
- The unit shall be 12V Safety Extra Low Voltage with a separate SELV transformer
- The unit shall be designed for surface or flush mounting using the fixing clamps provided, in walls, ceilings or mounting through glass using the GMK kit
- The fan shall incorporate an air operated backdraught shutter.
A rectangular cut out section shall be provided to connect to Xpelair Profile 29 flatduct using Xpelair kit Ref. 90547AA
- LVCF20 models shall be supplied with an outside grille
- LVDX200 shall be operated by a proprietary remote switch
- LVDX200T shall have an adjustable overrun timer (30sec-20mins) with 2 min start delay
- LVCF20 shall have automatic operation through integral humidity sensor, manual boost speed via pullcord and trickle ventilation
- LVCF20T shall have automatic operation through integral humidity sensor, manual boost speed via pullcord and trickle ventilation. Adjustable overrun timer (30sec-20min). 2 min start delay
- The unit shall be BEAB approved and rated at IPX5. The fan shall conform to Building Regulations for use in toilets, bathrooms and utility rooms
- The unit shall be suitable for zone 1 and zone 2 requirements as defined by IEE Wiring Regulations 16th Edition BS7674:2001
- The housing and stylish air inlet shall be moulded in high gloss white ABS
- The front cover shall be held in position by the retaining clips to facilitate removal and adjustment
- The motor shall be maintenance free, totally enclosed, fitted with sealed self aligning bearings and thermal overload protection
- Dimensions shall be W x H x D
222mm x 252mm x 118mm excluding spigot